Radiol. bras ; 40(6): 409-413, nov.-dez. 2007. graf, tab
Article in English, Portuguese | LILACS | ID: lil-472001

ABSTRACT

OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.


OBJECTIVE: The present study was aimed at evaluating the frequency of radiographic assessment of paranasal sinuses in pediatric patients in hospitals of Belo Horizonte, MG, Brazil. Additionally, aspects regarding radiation protection conditions and radiographic parameters were evaluated, and entrance air kerma and organ doses were estimated. MATERIALS AND METHODS: Patients' data and parameters of radiographic technique employed in the assessment of children in the age range between 1 and 16 years were collected in five examination rooms of four hospitals in Belo Horizonte, also taking into consideration the radiation protection aspects. Entrance air kerma calculation was based on the x-ray tubes output, and organ doses were estimated with the PCXMC software. RESULTS: Mean entrance air kerma values found in the five rooms were, respectively, 1398 µGy, 829 µGy, 877 µGy, 1168 µGy and 3886 µGy for patients with ages between 1 and 5 years. CONCLUSION: Most frequently, mento-naso and fronto-naso views are requested in conjunction in the majority of hospitals, which increases the radiation dose to the patients. It may be concluded that the risks for patients can be reduced by means of the utilization of an appropriate x-ray field, non-utilization of antiscattering grids, selection of high voltages and lower exposure times.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Radiation Exposure , Radiation, Ionizing , Dose-Response Relationship, Radiation , Sinusitis , Radiation Dosage , Kerma
SELECTION OF CITATIONS
SEARCH DETAIL